Alternative names, keywords |
Urine magnesium output, urine Mg |
Samples required |
Instructions for 24h urine collection available here or on UHSussex public site. |
Test indications |
|
Factors affecting test performance/ results |
No specific interferences noted. Results should always be assessed in conjunction with the patient’s medical history, clinical examination and other findings. |
Reference range |
3 - 5 mmol/ 24h Source: Roche Cobas® Magnesium Gen.2 kit insert, 2025-01, V18.0 |
Turnaround time |
Within 24h of acidification. |
Enquiries |
Biochemistry (Automation) |